AVPP12VR 12V
AVPP24VR 24V

Battery Protection

The Amber Valley Power Protectors are the latest generation of battery protection. The Power Protector constantly monitors the battery voltage and warns if it drops below a predetermined level. If the vehicle’s ignition is on, the Power Protector will constantly warn the driver without automatically disconnecting all circuits passed through it. If the ignition is off, the Power Protector will automatically disconnect all circuits passed though it after one minute from the warning.

  • Latest generation battery protection
  • Quick and easy to install
  • Remote isolation feature as standard
  • Available in 12V and 24V
  • Can Bus and Multiplex compliant
  • Operating temperature -40°C - 120°C
  • High peak current capability to 1800A
  • Continuous rating to 190A
  • Negative & Positive inhibits
  • Shock resistant to 40G
  • Automatic battery monitoring
  • Double latching technology
  • Override bleed facility
  • Solid State Electronics completely encapsulated against water, acid, oil and dust
  • OEM Specification

Technical Specification

  AVPP12VR AVPP24VR
Cut off voltage 12V 24V
Quiescent current 1.2mA 1.2mA
Warning Current (max) 3A 3A
Delay to warning 2 min 10 secs 2 min 10 secs
Warning duration 7 secs 7 secs
Delay to off from warning 1 min 5 secs 1 min 5 secs
Buzzer Yes Yes
Remote isolation Yes Yes



AVPP12VR15C 12V
AVPP24VR15C 24V

With speech alarm

Battery Protection

The Amber Valley Power Protectors are the latest generation of battery protection. The Power Protector constantly monitors the battery voltage and warns if it drops below a predetermined level. If the vehicle’s ignition is on, the Power Protector will constantly warn the driver without automatically disconnecting all circuits passed through it. If the ignition is off, the Power Protector will automatically disconnect all circuits passed though it after one minute from the warning.

  • Latest generation battery protection
  • Quick and easy to install
  • Remote isolation feature as standard
  • Available in 12V and 24V
  • Can Bus and Multiplex compliant
  • Operating temperature -40°C - 120°C
  • High peak current capability to 1800A
  • Continuous rating to 190A
  • Negative & Positive inhibits
  • Shock resistant to 40G
  • Automatic battery monitoring
  • Double latching technology
  • Override bleed facility
  • Solid State Electronics completely encapsulated against water, acid, oil and dust
  • OEM Specification

Technical Specification

  AVPP12VR AVPP24VR
Cut off voltage 12V 24V
Quiescent current 1.2mA 1.2mA
Warning Current (max) 3A 3A
Delay to warning 2 min 10 secs 2 min 10 secs
Warning duration 7 secs 7 secs
Delay to off from warning 1 min 5 secs 1 min 5 secs
Spoken warning Yes Yes
Remote isolation Yes Yes